Fluorine-butterfly axial-flow pump flow insufficient

1, the blade installation Angle is too small; Methods: to adjust the blade installation Angle.

2, head high; Methods: try to adjust the head, check the water pipe with and without obstruction.

3, cylindrical blade wear and damage of blade; Methods: replace the blade.

4, rotational speed did not reach the rating; Methods: eliminate the prime mover.

5, vane, guide vane, or around on the trash rack has sundry; Methods: to remove debris.

fluorine-butterfly axial-flow pump appear abnormal noise vibration circumstance

1, imports into the air cavitation occurred; Methods: water level.

2, the water level is too low, the impeller submerged depth; Methods: installation height or forward into the water level drop

3, rotor imbalance remaining component is too large; Methods: take out the rotor balance school again.

4, fluorine-butterfly axial-flow pump operation have abnormal vibration and unstable; Water pump base anchor bolt is not tight or loose.

5, fluorine-butterfly axial flow pump at different heart is imperfect, the motor shaft and the water pump shaft or the shaft bending; Processing method: root reinforcement, reinstall the proofreading, will drive shaft alignment.

6, guide bearing or sleeve serious wear and tear, and the rolling bearing damage failure; Methods: replacement of guide bearing or sleeve, change of rolling bearing.

7, various fasteners, don't drive a nut loose or toes in prison; Methods: review and tighten the fasteners, bolts, reinforce the foundation.

8, fluorine-butterfly axial-flow pump water or flow not lack; More common output pipeline pumps, no equipment one-way valve or one-way valve seal is lax.

fluorine-butterfly axial-flow water pump appear without water

1, the pump options wrong direction; Methods: adjust the prime motor rotation direction.

2, import be blocked; Methods: to remove imported stuff.

3, siphon outlet, height is too high; Methods: drop height.

4, leaf fixed failure; Processing method: check the blade, impeller fixed equipment, to adjust the blade installation Angle.

5, lose the geomagnetic immediately stop; In the use of lining fluoride axial flow pump is necessary to choose and employ persons in the care, present wrong immediately suspend, after the water pump did not turn check.


With technology speeding up in lighting speed, have created quite a name for itself amidst winter cover pump and it happens to have a lot of benefits as well.
To understand how efficiently works, go to J&T INDUSTRY for more information.
Millions of women across the world suffer from pool cover drain pump. Are you also one of them who suffer from acne problem? now you will see some hope in J&T INDUSTRY CO.,LTD.'s offer of . Click J&T INDUSTRY to know more.
J&T INDUSTRY CO.,LTD. has unique staffs who will serve you with their best ideas by affording you with high-quality service.
But we do think that reckoning with supply chains of submersible pump is a really important step. Even super simple switches in material, or sourcing, or shipping, or worker benefits seems like good place to start.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: