Just to create the best lamps.

J&T

Desulphurization pump thrust bearing surface damage causes and solutions are there?

by:J&T     2020-06-22
Desulphurization pump is a pump with anticorrosive wear-resisting, usually used in desulfurization of brick factory, industrial acid and alkali water, power plant desulfurization, etc. , for the water pump bearing thrust what are the reasons of surface burning, need to how to solve? Five units of a certain power plant desulphurization pump, between the pump and motor using elastic coupling of synthetic, often occurs in the operation of the motor bearing auxiliary thrust surface wear burning phenomenon, loss of lateral thrust tile are water pump, and the accident occurred in the pump start-up moment. To solve such problems, after repeated practice and analysis, find out why, and formulated the operation specification and the technical retrofit scheme, obtain good effect. One, the causes of the motor thrust bearing surface burning loss according to the laws of the failure and the structure characteristics of the pump, we think the cause of motor thrust bearing surface burning loss is due to the pump rotor runtime large axial thrust on the motor thrust bearing surface. The axial force was passed by the elastic coupling of synthetic. Below for detailed analysis of this view. rotor axial force balancing device, the pump starts, due to the stress balance room has not yet been established, the balance disc, thrust disc axial force balance role temporarily, after the balance room set up pressure, thrust plate only play a supplementary role, thrust plate and auxiliary driving face the gap between the 2 mm, auxiliary surface play a pump shut down the limit of rotor axial displacement of the largest negative effect, large displacement value of 2 mm. When pump idle away after the shutdown process, the rotor in the balance of chamber pressure and pump fluid flow under the action of inertial forward, to the high pressure pump rotor end up still, thrust disc is clingy auxiliary push and stop, and due to the coupling transmission torque is small, idle walk between the two with the pump and motor can pass through the friction of synthetic axial force is small, the motor rotor basic axial position in the run will stop, in this way, every time after stopping the pump, the motor rotor and the pump rotor in axial distance of about 2 mm. The pump is started again, because the starting torque is large, two and a half of the friction between the wheel is very big, when the pump rotor balance disc to be near balance board up to low voltage side, will drive the motor rotor to move away from the direction of the pump. So after stop repeat many times, the distance of the two rounds of S increases gradually, until before the start of motor rotor has been parked in the axial limit position, the motor shaft thrust plate has stick motor thrust bearing surface. And if in this case the feed water pump, the balance disc and thrust plate has yet to play a role, the axial force of pump rotor will be through the coupling to the motor rotor, causing the motor thrust face burned. Because of the failure is a prerequisite for the pump, after many start-stop motor and pump rotor axial distance increases to limit position, start the pump and in this case. Aiming at this characteristic, the method of simple force, to avoid the fault is in the pump before the start of each time, human will be resumed the distance between the pump and motor rotor to the standard position ( S = 5 ~ 7毫米) 。 This avoids the limiting case, to avoid the failure. The radical way to solve this problem is to improve the coupling. Due to the action of external force stop the pump when the pump rotor axial channeling move to high end, and the motor idle when the axial force is small, as long as the chosen type coupling will end in order to ensure the pump and motor rotor axial distance between in many times after start-stop still conform to the standard operation. To facilitate the installation, we please zhengzhou institute of machine tool design and manufacture the gear coupling, when installation does not need to do any changes on the original equipment foundation.
J&T INDUSTRY CO.,LTD. have long believed that management practices are an important element in productivity.
At the heart of water pump is our Vision to be the global energy company most admired for its people, partnership and performance.
Natural has the distinct pool cover drain pump which is irreplaceable.
Equipping water pump with innovative technology and updated processes will simplify daily compliance duties so that they can focus on attracting, retaining, and developing the most engaged workforce possible.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: