Just to create the best lamps.

J&T

Water ring vacuum pump maintenance and daily maintenance and matters needing attention _

by:J&T     2020-07-04
Water ring vacuum pump maintenance and daily maintenance

( 1) The purity of the oil level and oil should be paid attention to. The new pump should be replaced every 150 hours, after that every 2 - Replaced every three months if the poor operating conditions, when vacuum reduction, oil change time will shorten.

( 2) Keep the pump and pump chamber dry and clean.

( 3) Always pay attention to the temperature of the cooling water and oil. The highest temperature does not exceed 85 ℃, cooling water inlet temperature 30 ℃, the outlet temperature is not more than 5 ℃, the water clean.

water ring vacuum pump maintenance note

( 1) Regularly check whether the water ring vacuum pump pipe and joint loose rotation water ring vacuum pump with the hand, see whether the water ring vacuum pump flexible.

( 2) To add bearing lubricating oil bearing body. Observe the oil mark the centerline of the oil level. Lubricating oil should be timely replacement or supplement.

( 3) Tighten the town water ring vacuum water pump body of diversion water injection ( Or mud) 。

( 4) Close the outlet pipe of gate valves, outlet pressure gauge and vacuum gauge entrance.

( 5) Jog machine, look at the motor rotation is correct.

( 6) Start the motor. When the normal operation of water ring vacuum pump, open the outlet pressure gauge and the inlet water ring vacuum pump. After the show the proper pressure, and gradually open the gate, at the same time check the motor load.

( 7) Try to control the flow of water ring vacuum pump and head on the signs indicating range, to ensure that the water ring vacuum pumps running at peak efficiency, so as to achieve maximum energy saving effect.

( 8) During the running of water ring vacuum pumps, bearing temperature shall not exceed the environment temperature to 35 c, the highest temperature should not exceed 80 c.

( 9) If found abnormal sound in the water ring vacuum pump, stop the machine immediately to check the reason.

( 10) Water ring vacuum to use pump stop, first close the gate valve, pressure gauge, then stop the motor.

( 11) Water ring vacuum pumps should be run in the first month of 100 hours after oil change, then once every 500 hours to replace lubricating oil.

( 12) Adjust the packing gland on a regular basis to ensure that leakage normal packing chamber ( Suggest dropwise leaks) 。

( 13) Regularly check the wear condition of shaft sleeve, wear a big change in time.

( 14) , water ring vacuum use in winter to stop after, should be unscrewed a drain plug at the bottom of the pump body, medium completely empty. To prevent the frost crack.

( 15) Water ring vacuum pump has stopped for a long time. Water must be completely sealed pump, and dry, with oil daub rotating parts and connectors, and properly stored.


This is an internationally recognized standard which acts as a form of guarantee that everything J&T INDUSTRY CO.,LTD. does is managed to the highest quality standards.
We want to continue to organize JT to make it more efficient and profitable so that both, our clients and our employees can get more out of their time.
water pump allows users to apply in different ways for satisfying their needs.
We persevere in keeping the customers pleasant and supporting them with water pump at a reasonable price.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: