Just to create the best lamps.

J&T

Metering pump not amount on how to deal with?

by:J&T     2021-01-25
Metering water pump have numerous advantages, shortcomings also has many, but this does not affect its status in people's minds. In the mechanical manufacturing industry, the use of metering pump is relatively wide. Words, metering water pump not amount on how to deal with? Do you know? Please move on, don't know friends in the following, you will find the answer.

can cause of diaphragm metering pump in quantity are many, small make up here will introduce one by one to you. First of all, it is recommended that you check the line, because in the process of metering pump work, some garbage may enter inside the pump body, leading to line congestion. If the pipe is blocked, it will appear in quantity, at the time of such problems, as long as you check in time line, clean up garbage and waste. Furthermore, we are going to have a look at the pipeline valve, see if there are open. Pipeline valve is to be open, otherwise, there is no amount on the possibility. Secondly, it is recommended that you put the line of sight in plunger packing. Generally speaking, the place should not leak. If leakage occurs, it can also cause not on this situation. Want to solve this problem, you only need to timely adjust the packing gland. If after the adjustment, the problem is still appeared, then we will need to change the new packing. Replacement of new packing does not need to spend too much money, you don't worry about it. In electromagnetic metering pump is not on this problem, many friends will panic and feel metering pump is no way to remedy, in fact is not the case. On the metering pump is not the problem may be related to suction fluid level is too low, adjust the suction liquid level height, problem solved. At the same time, it is recommended that you keep an eye on the diaphragm or discharge tube place, take a look at the joint of two places is sealed tightly? Seal is lax, timely adjust. As for how to adjust, to find out the location of the leak, and resolve. Must find accurate leak location, otherwise, the. In the end we need to pay attention to is to fill the oil in the oil system, some of the oil quality is bad, it contains many impurities, that will also affect the functioning of metering pump. At this point, it is recommended that you change in time clean oil. Pay attention to. Must choose good quality, such not only can not solve this problem, will also be able to extend the service life of metering pump, to prevent the occurrence of many faceted after failure.


The submersible pump approach to pool cover drain pump is becoming increasingly popular; consequently, there is a surge in the demand for .
J&T INDUSTRY CO.,LTD. attaches great importance to customers and assists them in achieving their demands.
In the boundless Chinese market, there are a number of enterprises that provides winter cover pump submersible pump of their own brand over the years, but few have won more support from customers on the international stage than JT.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: