1, centrifugal water pump suction, pressure gauge throbbing. Reason: perfusion of water diversion is not enough; There is air pump inner product; The suction pipe and pipe leakage. Solution: pouring enough water diversion; Check the line to eliminate leakage phenomenon. 2, vacuum gauge indicates high vacuum, the pump is still not bibulous. Reason: the bottom valve didn't open or serious congestion; Suction pipe resistance; On the suction height is too high. Solution: check the bottom valve valve flexibility; To remove a blockage; Try to make simple suction pipe; Reduce the suction height. 3, water pump vibration reasons: pump shaft and motor shaft is different; Impeller imbalance; Bearing clearance is too large. Solution: adjust the pump and motor axis alignment; Through balance test of impeller unbalanced weight requirement at about 3 g; Replace the bearing. 4, water pump bearing heating reasons: lack of oil bearing and much lubricating oil viscosity; Bearing wear clearance is too large; Different heart pump and motor. The solution: come on; Changing the oil or low viscosity oil; Replace the bearing; Adjust the pump and motor, guarantee the concentric. 5, export pressure gauge indicates pressure, pump water little or no water. Reason: outlet pipe resistance; Steering is wrong; Impeller block; Speed is not enough. Solution: reduce pipe resistance; Check the motor steering; Remove the impeller blocking object; Increase the speed. 6, water pump power consumption is too large. Reason: too tightly on the packing; Packing room fever; The impeller wear; Water pump is too large. The solution: relax gland; Replacement impeller; Turning down the gate valve; Reduce the traffic. 7, water pump noise big reason: pump and motor installation different heart; The pump and motor bearing wear, have to beat. Solution: adjust the pump and motor, assure concentric; Replace the new bearing. 8 abnormal sound, water pump, pump without water. Reason: the suction resistance is too large; Suction height is too large; There are air into the suction pipe; Deserves to send liquid temperature is too high. Solution: check whether there is any jam on suction pipe; Clean up the bottom valve, reduce the liquid temperature or lower suction height. 9, the pump flow is lower than the design flow. Reason: the impeller blocking; Sealing ring wear clearance is too large; Speed is not enough. Solution: remove blockage; Replace the sealing ring; Increase the speed to the specified value on the nameplate.
water pump winter cover pump, as the name suggests, find extensive use in pool cover drain pump institutions. Since winter cover pump has become much dependent on technology in today's world, there is wide use of such water pump.
J&T INDUSTRY CO.,LTD. endeavors to be valued as an industry leader in client satisfaction, sales growth, product performance, financial strength and profitability.
We sells water pump and focus on operational procedure and manufacturing facilities pool cover drain pump.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: